Combi 25 - 29 simplified system II.

Combi 25 - 29 simplified system II.
2 5092509

Celsius Combi 25 - 29 simplified package II. content:

  • Celsius Combi 25 - 29 boiler
  • Pellet adapter door for connection pellet burner
  • Pellet burner - screw feeder
  • Pellet tank
  • Celsius anticondensing recycling pump unit
  • Celsius safety heat exchanger
  • System controller (Euroster 11E)
  • Celsius Combi boiler

    With pellet adapter door

    Celsius Combi boiler

     

    The Celsius Combi Boiler is our most up to date boiler.

    Celsius Combi boilers were developed to operate with either dry wood or wood pellet (DIN+ quality, 6 mm diameter thick). Its structure is similar to that of a traditional wood burning boiler, however, its operation is a lot more economical with the use of highly efficient equipment. The boiler requires minimum maintenance and will continue to meet your heating requirements over its long lifetime. The boiler can be connected to any kind of central heating system, from radiator to floor heating.

     

    The Celsius Combi Boiler with Wood Pellet burner is efficient and convenient because of:

    • Automatic turn on and turn off switching
    • Keeping fire and modulation (5 performance levels)
    • Increased savings due to possibility of 4 different pellet quality parameters.
    • Faster cleaning

     

    These boilers are suitable for burning wood and in auto mode Wood Pellets may also be used. Thanks to its special design the boiler can utilize both fuels with outstanding efficiency. Celsius boilers are suitable for gravity or pump controlled heating systems for family houses, workshops, various farm houses, agricultural halls, institutions and greenhouses. Celsius solid fuel burning boilers have different models which are sized by heat output to meet your individual requirements.

     

    Accessories:

    • Fire grates (grills) 
    • Wooden pellet burner adapter door
    • Filling/draining trap

     

     

     

    Mark

    Description

    A

    Height of boiler

    B

    Width of boiler

    C

    Depth of boiler

    1

    Boiler body

    2

    Exterior cover

    3

    Return water connection

    4

    Filling/draining tap connection

    5

    Upper door

    6

    Ash pan

    7

    Firing door (wood burning)

    8

    Pellet burner adapter door

    9

    Ash removal door (primary draught regulator)

    10

    Door opening handle

    11

    Firebox

    12

    Heat exchangers

    13

    Grate (grill)

    14

    Safety valve or pressure guage

    15

    Uptake connection

    16

    Forward water connection

    17

    Thermometer connection

    18

    Automatic draugh regulator connection

     

     

     

    TECHNICAL SPECIFICATIONS
    Modul Combi 25 - 29
    Firing door size (mm) 310*330
    Maximum heat output (kW) wood/pellet 33/29
    Heating-system dependant heatable air-space(m3) 300-500
    Fuel-dependant efficiency (%) wood/pellet 85/92
    Heating water connection (") 2
    Uptake connection (mm) 132
    Height (mm) 1140
    Width (mm) 555
    Depth (mm) 565
    Weight (kg) 188
    Water volume (l) 73
    Max. operating pressure (bar) 2
    Max. operating temperature (°C) 90
    Test pressure (bar) 4
    Draught demand (g/s) 31,8
    Firebox size (mm) (height*width*depth) 520*330*400

     

     

     


     

     

     

    Celsius safety heat exchanger

     

     

    It protects the boiler and environment if the boiler is overloaded and the heating system can not heat distribute (There is not buffer tank and irregular usage).

     

    Content of equipment:

    • Celsius safety heat exchanger
    • Vent valve
    • Thermostatic security valve (opening temperature 98°C)
    • Pressure security valve (2bar)

     

    Applicable to the following boiler types:
    Celsius classic, Celsius C and Celsius Combi boiler

     

     

     

     


     

     

     

    Celsius anticondesing recycling pump unit to 56 kW

     

    Celsius anticondensing pump unit

    Properties:

    • Complete assembled units.
    • Space-saving, it has minimal space requirement due to compact design.
    • Insulated, the assembled units have an insulating cover.

     

    Application:
    The anti-condensing pump unit can be connected directly to the solid heating source in the heating system or to the buffer tank without any additional device. The pump unit is housed in a compact insulation box which includes the circulation pump, the anti-condensing thermostatic valve, the on/off natural circulation clapet valve, the isolating valves and thermometers. It automatically adjusts the returning water to the heating source at the selected thermostat value setting.

     

    Technical features:

    • Synchronous high efficiency Wilo Yonos Para RS/7-RKC circulating pump with progressive speed control.
    • Max. working pressure 10 bar
    • Max. temperature 100°C
    • Setting temperature 55°C
    • Natural circulation clapet valve: with external control, it can be set on or off according to the type of installation.
    • Temperature thermometers: 0-120°C.

     

    Nominal opening temperature: setting temperature + 10 K.
    The max. usable power up to 80 kW (at Δt 30 K) with synchronous circulating pump Wilo Yonos RS/7-RKC.

     

    Working mode:

     

     

     

     

    Starting the installation (boiler warming up):
    After the starting of the boiler, the thermic valve is fully closed towards the user’s return (gate A) and this condition remains until the fluid, warmed up by the heating source, gets the opening temperature of the thermic valve (corresponding to the setting value, f.i. 55°C). During this step the fluid sent by the boiler fully recycles through the by-pass (gate B) and the boiler temperature rises very quickly.

     

     

    Loading the installation (tank warming up):
    Achieving the opening temperature (f.i.55c), gate valve A proportionally starts to open while gate valve B proportionally starts to close. The boiler temperature slowly rises providing energy to the user, however the return temperature will not decrease below the setting temperature (f.i. 55c)

     

     

    Working installation:
    Starting from the condition of point 2, the supply temperature progressively rises up to the full opening of the thermic valve (gate A) and up to the corresponding shutting of by-pass (gate B). This happens at about 10 K more than the opening or setting temperature (therefore in the example in hand, at about 65°C). Now the installation is on working and the supply fluid temperature can rise up to the set value.

     

     

    Natural circulation:
    The natural circulation of fluid through the clapet valve starts as soon as the circulating pump stops and the remaining energy of the heating source is transferred to the water tank. This function starts as a security device, when the pump stops due to blackout or failure, so avoiding that the temperature of the heating source can reach high levels of danger. To turn on the natural circulation function please turn the control screw anti-clockwise.
    You can lock the clapet valve any time, turning the screw clockwise (this operation has to be done when the pump is working).

     

     

     

     


     

     

     

    Euroster 11E pump controller

     

    11E vezérlő egység

     

    Central heating/Utility hot water system pump controller

     

    Euroster 11E is a modern microprocessor-based controller used to control central heating (CH) system pump or utility hot water (UHW) system pump.

    The Euroster 11E controller features the ANTY STOP function that prevents idle pump rotors against seizing. Once the heating season is over, every 14 days the function automatically turns ON the pumps for 30 seconds. To that end the controller must be left powered up.

     

    The Euroster 11E controller may be operated in two modes: it may control CH system pump or UHW system pump. In the former mode the CH system pump is engaged if sensor temperature has exceeded the preset limit. In the latter mode the UHW system pump is kept running until sensor temperature reaches the preset value.

    • Set 1 has been complied for layouts in which CH system pump is control,
    • Set 2 has been complied for layouts in which UHW pump is controlled.

     

    Connection diagrams

     

    Central heating pump control mode:

     

     

    1. Euroster 11E controller
    2. CH boiler
    3. Heat source temperature sensor
    4. CH pump
    5. Radiator (heat load)

     

    Domestic hot water pump control mode:

     

    11E hot water diagram

     

    1. Euroster 11E controller
    2. DHW tank temperature sensor
    3. DHW tank
    4. DHW pump
    5. CH (wood pellet) boiler
    6. CH pump
    7. Radiator (heat load)

     

     

    Elements of the controller:

     

    11E display

     

    1. Name of the controlled parameter
    2. Heat source (boiler) 
    3. Manual operation mode (icon lit while the temperature is manually controlled)
    4. Alarm – (icon blinks in case of an alarm)
    5. State of the heat source
    6. DHW system pump icon lit while the pump is running
    7. CH system pump icon lit while the pump is running (CH system control mode)
    8. Heat source and other parameter value
    9. DHW tank temperature sensor icon
    10. Menu option number

     

    Technical features:

     

    Min. temperature Max. temperature
    Controlled temperature 20 80
    Hysteresis 2 10
    Temperature sensor correction -5 5
    Manual operation 0 (ki) 1 (be)

     

     

    Operating voltage 230V, 50Hz
    Ratted wattage 1,6W
    Output load of circuit pump 200W
    Potential independent output 100W
    Environmental temperature 0 - 65°C
    Temperature measurement range 0 - 110°C
    Operation temperature range 20 - 80°C
    Hysteresis 2 - 10°C
    Temperature accuracy 1°C
    Protection IP40
    Display LCD

     


     

     

     

     

    B-Max 30 kW pellet burner equipment

     

    Pellet burner


    Low-power burner, designed for civilian buildings. It is equipped with a screw pump for loading.
    Bmax Technology burners have an innovative self-cleaning system which works on regular intervals: with this system the fuel grid is periodically freed from possible residue that could interfere with the correct combustion or that could induce the suffocation of the flame. In this way, the possibility of turning off the burner and the consequent dispersion of fumes are avoided.

     

    Safety equipment:

    • The B-Max 30 kW pellet burner contain safety equipments:
    • Burner safety thermostat (for preventing backfire)
    • Cutting valve fire (optional) (for preventing backfire)

     

    Accessories:

    • Screw (60 mm)
    • Pellet tank (200 kg)
    • Compressed air kit

     

    Parts of wood pellet burner:

     

    Pellet burner

     

     

     

     

    Description

    Measurement

    B-Max 30 kW

    Burner output

    kW

    12÷34

    Electric connection

    V~Hz

    230~50

    Average energy consumption

    W

    60

    Lighting

    W

    170

    Fuse (delayed)

    A

    3,15

    Noise level

    dBA

    35

    Height of flame

    mm

    200

    Min. combustion chamber (height)

    mm

    300

    Min. combustion chamber (width)

    mm

    300

    Min. combustion chamber (depth)

    mm

    350

    Draught demand

    Pa

    20

     

     

    Size and weight of screw feeder:

     

     

     

     

     


     

     

     

    Wood pellet tank

     

    Celsius pellet tank

     

     

    Celsius wood pellet tank with wheels and  cover. Easy to take out pellet.

     

    Sizes:

    • Height: 1270 mm
    • Width: 820 mm
    • Depth: 820 mm
    • High width screw feeder: 1900 mm

     

  • Weight
    305 kg/pc