Scald protection valve with timer circulation pump

35 - 60°C 4Kvs

 

Hot domestic water recycling kit for storage with coils and circulating pump

Features:
The kit allows to connect the recycling way of the hot domestic water to an instantaneous storage tank with coils in a very simple way. The pre-assembled kit, by means of a stainless steel flexible pipe, makes a counter-current circulation that warms the water along the recycling way.

 

High performance adjustable thermostatic diverting valves. Its material is yellow brass.
The pre-assembled kit, by means of a stainless steel flexible pipe, makes a counter-current circulation that warms the water along the recycling way.

 

Technical specifications:

  • Maximum static pressure 10bar(PN10), dinamic 5bar
  • Maximum ratio between the pressures: 2:1
  • Maximum inlet temperature: 95°C
  • Setting temperature range: 35-60°C
  • Setting stability: ± 2°C
  • Maximum Kvs: 4,0 (82 l/min, 1,5 bar)

 

Hydraulic scheme
Lowara Ecocirc Pro 15-1/65 circulating pump.
The headloss of the DomvS Circ 1 kit is measured between the points A and B of the hydraulic scheme.

 

 

The scald protection function stops automatically the hot water running if the cold water of necessary
mixing is not enough.

 

Recycling working way:
When the circulating pump starts, the cold water into the recycling loop, flowing through the flexible pipe, comes back warmed towards the gate H of the mixer; the gate C of the mixer is usually closed until when the temperature of the recycling loop is approaching to the one selected on the mixer (this condition rarely occurs). The recycling circulation into the recycling loop is working until the temperature is sufficient.

 

scald protection with timer circulation

User

  1. Expansion vessel
  2. DHW scald protection unit
  3. Circulating pump and check valve
    (included only in the models R and RU)
  4. Security valve
  5. Storage tank

 

A and B. Measuring points to determine the headloss.

 

The tests are finished in the laboratory with 1 bar differential pressure just the valve itself:
DN20 Kvs 4,0, the regulator in third position: Thot=65°C, Tcold=15°C, Tmix=51°C, (65l/min)