One circle secondary electronic heating system

One circle secondary electronic heating system
491

Heating pump units for radiator and floor heating - Electronic (servomotor) mixing valve

Content of package:

  • Heating pump unit with servomotor mixing valve (built-in by-pass)
  • Euroster 11M controller
Details

Pump unit with electronic mixing valve

 

 

Heating circuit supplier pump unit
Advangates:

  • Space-saving, compact design
  • Insulated, aesthetic
  • Quick and easy assembling
  • Mechanic friend therefore is more economical to build up
  • Plannable mechanic costs
  • Adjustable heating water temperature per heating circuit
  • Reasonable price/value rate
  • Long lifetime for the best quality components

 

 

Pump unit with servomotor mixing valve 3/4”
2-WAY PUMP UNIT WITH 3-WAY MIXING VALVE WITH BUILT-IN BY-PASS 0-50%

DN20 pump units can be connected to heating systems with powers up to 33kW, with a very
low energy consumption assured by high efficiency synchronous circulating pumps.

 

EPP insulation box (Measurements: 180x302x142 mm).
Centre distance 90 mm.
Especially suitable to manage medium-low powers in small rooms,
thanks to its centre distance of only 90 mm.
For power up to 33 kW (with Δt 15 K).
Maximum flow 1900 l/h.
Kvs value: 5.5
For an accurate measuring or for higher flows, please refer to the curves shown in the next page.

 

The unit for 1/2” (130 mm) circulating pumps consists of:
Supply:

  • Connection.
  • 3-way mixing valve with adjustable by-pass. Through the bypass
    (adjustable from the front part) it is possible to mix on the
    supply line a quantity of water coming back from the return
    line of the system, from 0 up to 50%.
  • High efficiency synchronous pre-wired circulating pump (for the models that include it).
  • Flanged ball valve supplied with in-handle thermometer (coded red, range 0°C-120°C).

Return:

  • VFlanged ball valve with non return valve 20 mbar (which can be excluded by rotating the handle by 45°)
    supplied with in-handle thermometer (coded blue; 0°C-120°C).
  • “T” Connection for mixing valve.
  • Connection.

 

 

Approximate data  for applications in low and medium temperature heating systems

t

Approximate power and flow of the installation

Recommended circulating pump

Residual lifting power

Approximate surface of the underfloor heating system

8 K

12 kW - 1300 l/h

Wilo Yonos Para RS 15/6

4,5 mH₂0

Up to 100 m²

8 K

17 kW - 1900 l/h

Wilo Yonos Para RS 15/7,5

5 mH0

Up to 170 m²

15 K

23 kW - 1300 l/h

Wilo Yonos Para RS 15/6

4,5 mH0

-

15 K

33 kW - 1900 l/h

Wilo Yonos Para RS 15/7,5

5 mH0

-

 

Working principle

 

During the regular working process, with the mixer completely closed on the recy cling for example, a part of the fluid is aspirated from the pump all along the by-pass line. This quantity of fluid (narrow blue arrow) represents 50% of the capacity of the mixer (red arrow). As a result, one has a very high delivery capacity and a reduced temperature.

 

 

 

 

 

 

servomotor

 

Servomotor TRM20:

 

3 points servomotor for mixing valve, bidirectional,
reversible.
Operating range of 90°, 230V, 105 s., torque 2 Nm. IP40.

 

 

 

 

 

 


 

 

 

Euroster 11M

 

 

Electronic, programmable controller designed for control of a three-way valve with actuator and CH circulation pump. It automatically maintains a constant temperature at a preset level or ensures a proper temperature of water in return piping in a CH system with coal-fired boiler. Possibility to connect a room thermostat. E11M controller is equipped with an AntiStop function which prevents seizure of the idle pump and valve rotor.

 

Controller function

  • keeps constant water temperature: in the central heating
    circuit or in boiler return
  • possibility of connecting room regulator
  • Anti-Stop function to protect pumps and valve against
    stoppage
  • frost protection
  • pump operation test
  • temperature reading correction

 

EUROSTER 11M operates in one of the two modes: heating medium temperature regulation (e.g. in floor heating) or return temperature stabilization. Operation mode is changed when restoring factory settings, provided for each of the modes.

Set 1: intended for system with heating medium temperature regulation

Set 2 intended for system with return temperature regulation

 

Technical specifications:

  • Power supply: 230V, 50Hz
  • Device controlled: mixing valve actuator, CH pump
  • Rated output load: 3 A 230 V 50 Hz
  • Rated power consumption: 1,6W
  • Operating temperature range: 5-40°C
  • Storage temperature range: 0-65°C
  • Temperature measurement range: 0-110°C
  • Temperature control range: 10-70°C (CH temperature congrol mode)
  • Temperature limit of starting pump unit: 20-80°C
  • Temperature control hysteresis: 2-10°C
  • Temperature control accuracy: 1°C
  • IP rating: IP40
  • Status visualization: backlit LCD
  • Colour: black
  • Mount method: wall-mounted, wall plugs
  • Weight (controller with cables): 0,76 kg
  • Certificates/standards: complies with the EMC and LVD Directives
  • Dimensions (W/HxD) mm: 150/90/52
  • Packing list: Euroster 11M controller, wall plugs, instructions,
    mounting template, sensor bands

 