One circle secondary electronic heating system 5/4"

-7%
One circle secondary electronic heating system 5/4"
868 

Az áthúzott ár az árcsökkentés alkalmazását megelőző 30 nap legalacsonyabb eladási ára.

810
Begin: 20/11/2023   While stocks last!

Industrial heating pump units for radiator and floor heating - Electronic mixing valve

Content of package:

  • Heating pump unit without mixing valve 5/4"
  • Euroster 11M controller
Details

Euroster 11M

 

 

Electronic, programmable controller designed for control of a three-way valve with actuator and CH circulation pump. It automatically maintains a constant temperature at a preset level or ensures a proper temperature of water in return piping in a CH system with coal-fired boiler. Possibility to connect a room thermostat. E11M controller is equipped with an AntiStop function which prevents seizure of the idle pump and valve rotor.

 

Controller function

  • keeps constant water temperature: in the central heating
    circuit or in boiler return
  • possibility of connecting room regulator
  • Anti-Stop function to protect pumps and valve against
    stoppage
  • frost protection
  • pump operation test
  • temperature reading correction

 

EUROSTER 11M operates in one of the two modes: heating medium temperature regulation (e.g. in floor heating) or return temperature stabilization. Operation mode is changed when restoring factory settings, provided for each of the modes.

Set 1: intended for system with heating medium temperature regulation

Set 2 intended for system with return temperature regulation

 

Technical specifications:

  • Power supply: 230V, 50Hz
  • Device controlled: mixing valve actuator, CH pump
  • Rated output load: 3 A 230 V 50 Hz
  • Rated power consumption: 1,6W
  • Operating temperature range: 5-40°C
  • Storage temperature range: 0-65°C
  • Temperature measurement range: 0-110°C
  • Temperature control range: 10-70°C (CH temperature congrol mode)
  • Temperature limit of starting pump unit: 20-80°C
  • Temperature control hysteresis: 2-10°C
  • Temperature control accuracy: 1°C
  • IP rating: IP40
  • Status visualization: backlit LCD
  • Colour: black
  • Mount method: wall-mounted, wall plugs
  • Weight (controller with cables): 0,76 kg
  • Certificates/standards: complies with the EMC and LVD Directives
  • Dimensions (W/HxD) mm: 150/90/52
  • Packing list: Euroster 11M controller, wall plugs, instructions,
    mounting template, sensor bands

 

 

 

 

2-way pump unit with 3-way mixing valve 5/4"

Pump unit with 3-way mixing valve 5/42

2-way pump unit with 3-way mixing valve and servomotor 5/4”
Circulation pump: Grundfos alpha 2L 32-60

 

DN32 pump units, thanks to a very careful measuring of the specific components, have all the force points of range, such as functional capacity, reliability and versatility of installation.

 

Dimensions: 250x400x170 mm (EPP insulation box)
Centre distance 125 mm.

 

They can be connected to heating systems with powers up to 111 kW, with a very low energy consumption assured by high efficiency synchronous circulating pumps Wilo Stratos Para and Grundfos Alpha 2L. the connections to the heating loop or to the distributor are made in 1”1/4 female thread.

For power up to 93 kW (with Δt 20 K)
Maximum flow 4000 l/h
Kvs Value: 13,0.

 

For an accurate measuring or for higher flows, please refer to the diagram.

 

 

The unit for 1”1/4 (180 mm) circulating pumps consists of:

Supply:

  • Connection.
  • 3-way mixing valve with electronic servomotor.
  • High efficiency synchronous pre-wired circulating pump (for the models that include it).
  • Flanged ball valve supplied with in-handle thermometer (coded red, range 0°C-120°C).
  • Temperature sensor.

Return:

  • Flanged ball valve supplied with in-handle thermometer (coded blue; range 0°C-120°C).
  • “T” connection with 20 mbar non return valve (ball valve side).
  • 5/4” connection.

 

Available circulating pumps:
Grundfos Alpha 2L 32-60
Wilo Stratos Para 30/1-7
Wilo Stratos Para 30/1-8